This study determines speed control of BLDC motor using a Bridgeless CukConverter (BCC) which enhance low conduction loss as well as lesser number of heat sink. Ascheme in which controlling voltage at output of BCC the variation in the speed of the drive is attained. Operation of cuk converter is carried out discontinuous inductor current mode at output inductance and continuous mode at input inductance and intermediate capacitors for better power factor and good power quality at AC supply mains for various speeds. On eliminating distorted currents at AC mains using filter technique to a BCC thereby improving PQ over suitable limits by IEC 61000-3-2. In this setup,supply ac mains is given to power converter. Power converter consists of BCC and VSI, voltage is varied from DC link and speed of the motor is regulated accordingly. Diode bridge rectifier(DBR) requirement is eliminated to obtain reduced conduction losses. Finally proposed system is validated in simulation and test results are obtained to get PFC at AC mains as well as operation of drive is smooth developing PQ for various range of speeds.

Original languageEnglish
Pages (from-to)821-832
Number of pages12
JournalInternational Journal of Control Theory and Applications
Volume9
Issue number2
Publication statusPublished - Jan 1 2016

Fingerprint

DC-DC converters
Power converters
Inductance
Heat sinks
Electric potential
Speed control
Power quality
Diodes
Capacitors

All Science Journal Classification (ASJC) codes

  • Computer Science(all)

Cite this

@article{943452e34f2d4642a4909c500b637bc1,
title = "Design and implementation of Bridgeless Cuk Converter for controlled BLDC motor",
abstract = "This study determines speed control of BLDC motor using a Bridgeless CukConverter (BCC) which enhance low conduction loss as well as lesser number of heat sink. Ascheme in which controlling voltage at output of BCC the variation in the speed of the drive is attained. Operation of cuk converter is carried out discontinuous inductor current mode at output inductance and continuous mode at input inductance and intermediate capacitors for better power factor and good power quality at AC supply mains for various speeds. On eliminating distorted currents at AC mains using filter technique to a BCC thereby improving PQ over suitable limits by IEC 61000-3-2. In this setup,supply ac mains is given to power converter. Power converter consists of BCC and VSI, voltage is varied from DC link and speed of the motor is regulated accordingly. Diode bridge rectifier(DBR) requirement is eliminated to obtain reduced conduction losses. Finally proposed system is validated in simulation and test results are obtained to get PFC at AC mains as well as operation of drive is smooth developing PQ for various range of speeds.",
author = "Ahmed, {Shaik Fareed} and {Iyswarya Annapoorani}, K. and S. Ravi",
year = "2016",
month = "1",
day = "1",
language = "English",
volume = "9",
pages = "821--832",
journal = "International Journal of Control Theory and Applications",
issn = "0974-5572",
publisher = "Serials Publications",
number = "2",

}

Design and implementation of Bridgeless Cuk Converter for controlled BLDC motor. / Ahmed, Shaik Fareed; Iyswarya Annapoorani, K.; Ravi, S.

In: International Journal of Control Theory and Applications, Vol. 9, No. 2, 01.01.2016, p. 821-832.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Design and implementation of Bridgeless Cuk Converter for controlled BLDC motor

AU - Ahmed, Shaik Fareed

AU - Iyswarya Annapoorani, K.

AU - Ravi, S.

PY - 2016/1/1

Y1 - 2016/1/1

N2 - This study determines speed control of BLDC motor using a Bridgeless CukConverter (BCC) which enhance low conduction loss as well as lesser number of heat sink. Ascheme in which controlling voltage at output of BCC the variation in the speed of the drive is attained. Operation of cuk converter is carried out discontinuous inductor current mode at output inductance and continuous mode at input inductance and intermediate capacitors for better power factor and good power quality at AC supply mains for various speeds. On eliminating distorted currents at AC mains using filter technique to a BCC thereby improving PQ over suitable limits by IEC 61000-3-2. In this setup,supply ac mains is given to power converter. Power converter consists of BCC and VSI, voltage is varied from DC link and speed of the motor is regulated accordingly. Diode bridge rectifier(DBR) requirement is eliminated to obtain reduced conduction losses. Finally proposed system is validated in simulation and test results are obtained to get PFC at AC mains as well as operation of drive is smooth developing PQ for various range of speeds.

AB - This study determines speed control of BLDC motor using a Bridgeless CukConverter (BCC) which enhance low conduction loss as well as lesser number of heat sink. Ascheme in which controlling voltage at output of BCC the variation in the speed of the drive is attained. Operation of cuk converter is carried out discontinuous inductor current mode at output inductance and continuous mode at input inductance and intermediate capacitors for better power factor and good power quality at AC supply mains for various speeds. On eliminating distorted currents at AC mains using filter technique to a BCC thereby improving PQ over suitable limits by IEC 61000-3-2. In this setup,supply ac mains is given to power converter. Power converter consists of BCC and VSI, voltage is varied from DC link and speed of the motor is regulated accordingly. Diode bridge rectifier(DBR) requirement is eliminated to obtain reduced conduction losses. Finally proposed system is validated in simulation and test results are obtained to get PFC at AC mains as well as operation of drive is smooth developing PQ for various range of speeds.

UR - http://www.scopus.com/inward/record.url?scp=84975116941&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84975116941&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84975116941

VL - 9

SP - 821

EP - 832

JO - International Journal of Control Theory and Applications

JF - International Journal of Control Theory and Applications

SN - 0974-5572

IS - 2

ER -